TS-1775 Relay Test Set

© Brooke Clarke 2010

Background
Description
Tests
Use as Milliammer
Manuals
Related
Links

TS-1775 Relay Test Set
TS-1775 Relay Test Set Inside

Background

This test set is for relays.  It mainly tests the coil of the relay and so might also be useful for testing other electromagnetic coils.

Description

The test set requires an external battery which is connected by means of a three conductor cable terminated with a 1/4" stereo phone plug that mates with the "BG" soclet in the lower left of the front panel.

Connections


Binding
Post
BG
Jack
Function
BAT
Ring

GRD
Tip

T

Relay Test
R

Relay Return
S
Sleeve

Plug for BG can be PL-51, WE No. 110 or No. 310.
BG stands for Battery-Ground
a PP-3940/G Power Supply set to 10 Volts can be used on the BAT & GND inputs for testing the TS-1775.
the external BAT supply depends on the operation voltage of the relay under test.

Tests

Use as Milliammer

FINE 2: extreme CW
both OPERATE switches to 0
Meter range: 150 ma (to start)
Strap binding posts T & R (where the relay coil connects for most tests) and use BAT and GRD for the meter connection.
2-2 switch: toggle either up or down to read meter.

Manuals

TM 11-6625-202-14 Operator's Organizational, Direct Support, and General Support Maintenance Manual, Test Set, Relay TS-1775/U, NSN 6625-00-064-6096, October 1975

TM 11-6625-202-24P Organizational, Direct Support, and General Support Maintenance Repair Parts and Special Tools Lists (Including Depot Maintenance Repair Parts and Special Tools) for Test Set, Relay TS-1775/U, 4 Jan 1978

Related

Links

Fair Radio Sales
Back to Brooke's: PRC68, Products for Sale, Telegraph, Personal Home, List of all page